Pyranometer GSM 10.7 THIES Clima is used to measure global radiation. The measurement is cos-corrected.
Versions
As per 7.1415.05.xxx, but:
Product number 7.1415.05.041
Data output analog
Output type: 4 ... 20 mA
Power supply: 9 ... 28 V DC
Product number 7.1415.05.240
Data output digital
Protocol: ASCII
Output type: 2 wire RS485
Data output analog
Output type: 0 ... 20 mA
Power supply: 9 ... 28 V DC
Product number 7.1415.05.241
Data output digital
Protocol: ASCII
Output type: 2 wire RS485
Data output analog
Output type: 4 ... 20 mA
Power supply: 9 ... 28 V DC
Product number 7.1415.05.251
Data output digital
Protocol: ASCII
Output type: 2 wire RS485
Data output analog
Output type: 0 ... 5 V
Power supply: 9 ... 28 V DC
Product number 7.1415.05.261
Data output digital
Protocol: ASCII
Output type: 2 wire RS485
Data output analog
Output type: 0 ... 10 V
Power supply: 12 ... 28 V DC
Product number 7.1415.05.340
Data output digital
Protocol: MODBUS RTU
Output type: 2 wire RS485
Data output analog
Output type: 0 ... 20 mA
Power supply: 9 ... 28 V DC
Product number 7.1415.05.341
Data output digital
Protocol: MODBUS RTU
Output type: 2 wire RS485
Data output analog
Output type: 4 ... 20 mA
Power supply: 9 ... 28 V DC
Product number 7.1415.05.351
Data output digital
Protocol: MODBUS RTU
Output type: 2 wire RS485
Data output analog
Output type: 0 ... 5 V
Power supply: 9 ... 28 V DC
Product number 7.1415.05.361
Data output digital
Protocol: MODBUS RTU
Output type: 2 wire RS485
Data output analog
Output type: 0 ... 10 V
Power supply: 12 ... 28 V DC
Specification
Measuring range: 0 ... 1300 W/m²
Cosinus-correction: error f2 < 3 %
Spectral range: 380 ... 2800 nm
Non-linearity: <5 %
Abs. error: < ±10 %
Diffuser: PTFE
Dome: optical glass
Sensor type: thermocouples
General
Ambient temp.: -20 ... +60 °C
Electr. connection: plug with 5 m cable
Dimension: Ø 80 x 86 mm
Weight: 0.3 kg
Accessories
Traverse 0,8 m: For mounting of a Pyranometer CMP11 / 6 / 3 And a sunshine duration sensor-CSD3 onto a mast.
Hanger 1 m (for radiation sensors): The hanger is used to mount a radiation or brightness transmitter laterally onto a mast.
Adapter Compact: The adapter is used to mount a radiation, baro, or brightness transmitter onto a traverse (4.3171.30.000, 4.3171.40.000) or holder (506 347).
Adapter Compact 0 ... 90 ° adjustable: The adapter is used to mount a radiation, baro, or brightness transmitter onto a traverse (4.3171.30.000, 4.3171.40.000) or holder (506 347).